The JinJue Gas Turbine Intake Air Filter For Gas Turbine GE is an indispensable component of the gas turbine system, widely used in various fields such as power generation, aviation, and industry. Its main task is to filter out particulate matter and pollutants from the air before it enters the gas turbine engine.
Name of Item or Related Service | Technical Specification and Standards |
Gas Turbine Intake Air Filter For Gas Turbine GE(Cylindrical and Conical) For Gas Turbine GE | Filter media:100% Synthetic nonwoven water repellent composite media. |
Pleats:Pleats are to be stabilized spiral by hot-melt adhesive on both inner and outer cores. | |
No of Pleats and Media Area:No of pleats for cylindrical: ≥310 pleats Media Area for cylindrical: ≥18 m2 No of pleats for conical: ≥375 pleats Media Area for conical: ≥22 m2 | |
End caps:Galvanized | |
Open Liners (Inner & Outer):Galvanized carbon steel G90 to ASTM653 or greater | |
Construction:Full metallic Construction, Non-welded | |
Washer:Each filter set should be provided with 1 pc of standard Rubber coated washer for setting filter set on the tripod. | |
Gasket material:Single piece, seamless, skinned foam in place polyurethane (closed cell) or EPDM. | |
Gasket stops:Integrated into the conical filter preventing over compression of the gasket. Polyurethane foam shall be consistency that when 6-10FT-LBS of tightening on retention bolt, seal will be tight as to allow no dirty air by-pass. | |
Glue/Potting type:Polyurethane | |
Dimensions: Cylindrical:OD of Cap: Ø324 ID of Cap: Ø215Hole of ID Close End Cap: Ø30mm Length:660 Conical:Smaller End Cap OD: Ø324 Smaller End Cap ID: Ø215 Larger End Cap OD: Ø445 Larger End Cap ID: Ø330 Length: 660Note 1: Tolerance in Dimension ±3mmNote 2: Cylindrical + 1 Conical= 1Set and Outer dimension of Cylindrical should be same to the smaller end of Conical. | |
Weight:Cylindrical:Must not exceed 6kg cleanConical:Must not exceed 7kg clean | |
Air Flow Rate:2338m3/hr to 2980 m3/hr | |
Average Efficiency for 0.4 µm particles:≥95%(Test certificate required, tested by independent test house) | |
Efficiency Class:a) EN779:2012: F9(Test certificate should be submitted, tested by independent test house) | |
Dust holding capacity:≥2000g at a pressure drop of 4” WG(1000 Pa) using ASHRAE test dust: | |
Initial pressure drop at >2338m3/hr:<240Pa (0.96’’H2O) | |
Burst pressure, in both wet and dry condition:>6230PA (25’’H2O) | |
Humidity Range:0 to 100% relative humidity | |
Operation temperature range:-40 degrees C to +50 degrees C(-40°F to +122°F) |